Change Log

Home > Change Log


        
Date OS Product Release Description Download
2017-04-26Windows
VMWare
Intelligent Power Manager1.60 ========================================
Release note Intelligent Power Manager 1.60 Release Build 210
(May 2018)
========================================

UPGRADE INFO :
==============

* Automatic Update to IPM 1.60 is now possible from previous IPM Versions
Check the two IPM services "Eaton EMC4J" and "Eaton Intelligent Power Manager" are correctly stopped before launching the update process.


========================================
Release note Intelligent Power Manager 1.60 Release Build 204
(March 2018) ========================================

UPGRADE INFO :
==============
IPM 1.60 should only be used for a new installation.
Existing IPM 1.55 users should NOT upgrade to IPM 1.60. You will need to recreate your configuration policies in the new version.


New features:
=============
* Nutanix Cluster shutdown based on Acropolis Hypervisor
* New option to manage manually Duplicated nodes on discovery process
* IPM OVA package 64bit (based on Debian) including Open VM tools
* Dynamic group implementation for configuration policy
* vSAN : cluster shutdown managed by IPM (check Known issues section for configuration restriction)(1.56)
* Microsoft Hyper-V integration : remote agentless shutdown and remote agentless maintenance mode (1.56)

Improvements:
=============
* Correlation ID algorithm : reinforcing compare rules to determine duplicate nodes (IP address-SN-IPv6)
* NetApp compatibility with 9.1 OS (starting from 8.3)(1.56)
* HPE OneView 3.0 compatibility (1.56)
* VMware : Manage SRM connector and Manage Infrastructure shutdown (1.56)
* SCVMM is removed from connectors list (1.56)
* New Eaton Management Pack for OpenStack (Ocata release) brings Virtual Machine Power Optimized Placement capability to OpenStack users thank to IPM (1.56)

Bugs fixes:
===========

* HPE OneView compatibility restored with version 2.x and previous
* Hyper-V connectors available for IPM OVA package
* VMs graceful shutdown fixed for MS Hyper-V infrastructure connector
* VMs location update after a migration of VMs to one Esxi host
* ESXi 6.0: Hypervisor and Virtual Machine monitoring issues on IPM
* APC UPSs discovery
* Prevent Shutdown by IPM when UPSs switch on mechanical Bypass
* SCVMM connectors configuration still working after an upgrade but no more configurable (replaced by the new MS Hyper-V Connector)

New Known issues:
=================
* IPM is not compatible with Java 9 & 10
* IPM doesn't manage the vSAN cluster shutdown if Critical VMs are defined when configuring shutdown policy
* IPM Configuration Export/Import is not working by default in https mode.
Workaround : before importing IPM configuration on new server, it's mandatory to copy/paste the "key.pem" file from the old IPM instance to the new one.
* After a cluster startup on VMware environment, when the cluster restart, If all hosts and VMs have communication lost status, user has to restart IPM manually
* OpenStack connector is not functional in 1.60 even if it's possible to create it on IPM.


Cyber-security:
===============
Please, read carefully the cybersecurity note provided in Product Literature for information and recommendations about cyber-security.
* Unsecure HTTP connection deactivated by default
* Third party components library updated to the last components version
Intelligent Power
2017-04-26Windows
VMWare
Intelligent Power Manager1.55 ========================================
Release note Intelligent Power Manager 1.55 for Windows
(April 2017)
========================================

Improvements:
=============
* Improve usability of the action page
* Streamline third part UPS usage for gold IPM users
* Watchdog implementation to improve error management
* Add JAVA prerequisites and IPM license level information into IPM connector creation window

Bugs fixes:
===========
* Communication failure between IPM and IPP shutdown controller
* Discovery and Advanced monitoring of APC's UPSes: customized drivers
* Latest HPe network card is now discovered with standard driver
* Cisco connector default port error is resolved
* sendNotification and sendEmail "User Functions" are available from "User Scripts"

Cyber-security fixes:
=====================
* Prevent password jacking
* Restrict access privileges to mc2.db file
* Injection of XSS code from the authentication window is resolved

New Known issues:
=============
* Multiple infrastucture connectors may lead to communication issues; an IPM restart solves it
* Veaam replication software is not compatible with IPM VM management.
Intelligent Power
2017-03-16Windows, Linux, VMware & HP-UX (Itanium)Intelligent Power Protector1.53 ========================================
Release note Intelligent Power Protector 1.53 for Windows
(March 2017)
========================================

New features:
=============
* Added support for TLS 1.2 protocol
* Added support for Windows Server 2016
* Added support for VMware 6.5
* Added support for RHEL 7.3 & 6.8
* Added support for SLES 12 SP2

Bugs fixed:
===========
* Shutdown ESXi via IPP issue
* Installation issue on SLES 12 SP2
* Data acquisition issue with PXGX-UPS communication cards
Intelligent Power
2016-12-22Windows
VMWare
Intelligent Power Manager1.54 ========================================
Release note Intelligent Power Manager 1.54 for Windows
(December 2016)
========================================

New features:
=============
* New connector for Nutanix users:
** Discover all User Virtual Machines (UVM) running in your Nutanix cluster.
** Start/Stop UVM on any environmental or power event.
* IPM 1.54 is compatible with Windows Server 2016.
* IPM 1.54 is compatible with VMware 6.5.

Improvements:
=============
* Automatic upgrade server has been restored.
* More suitable timestamp format is used when exporting graph data.
* Added some logs for all actions run in OpenStack environment.
* Performance optimizations.

Bugs fixes:
===========
* Fixed some memory leaks that occurred when protecting virtualized IT infrastructures.
* Now the current password needs to be provided to change a password.
* Uninstall process is not leaving useless files on the disk anymore.
* Now grace period setting is taken into account for all events including events created by duplication.

Known issues:
=============
* Once the protection of an individual Virtual Machine is configured, if that VM is migrated to a new cluster and brought back to the initial one, its protection must be reconfigured.
* Actions on OpenStack infrastructure might not work just after a new connector configuration.
A restart of IPM service after each OpenStack connector configuration is recommended to avoid this issue.
* NetApp users might lose their connector after the upgrade to IPM 1.54.
In that case, remove the corresponding node, reconfigure the connector and review configuration policies and actions to replace all occurences of the initial node by the new one.

Cyber-security:
===============
Please, read carefully the cybersecurity note provided in Product Literature for information and recommendations about cyber-security.
Intelligent Power
2016-08-03Windows
VMWare
Intelligent Power Manager1.53 ========================================
Release note Intelligent Power Manager 1.53 for Windows
(June 2016)
========================================

New features:
=============
* New connector for HPE OneView users to discover and power cap servers on power or environmental events.
* New connector for OpenStack users compatible with Nova and Cinder Kilo release.
* Automatic matching of duplicated nodes.

Improvements
=============
* Better default node names.
* More stable ESXi shutdown behavior.
* Improved shutdown behavior for redundant configurations using an ATS device.
* Shorter feedback delay when changing an ePDU configuration.

Bugs fixes:
===========
* Fix misleading "access denied" icon for virtualized nodes.
* The "Power Source" value for a composite device with a custom name is not displayed with the correct name in configuration policies.
* Actions/Events menu: Sometimes event source of Action item displays incorrect value.
* Fix VMware issues where action is executed several times or locked in specific contexts.

Known issues:
=============
* The automatic upgrade server is not reachable.

Cyber-security:
===============
Please, visit www.eaton.com/cybersecurity to check the cyber-security status of this product and to subscribe to all cybersecurity alerts coming from Eaton.
Intelligent Power
2016-06-15Windows, Linux, VMware & HP-UX (Itanium)Intelligent Power Protector1.52========================================
Release note Intelligent Power Protector 1.52 for Windows
(June 2016))
========================================

New features:
=============
* New UPS Compatibility for Eaton 9PX 2.2kVA and Eaton 9PX 3kVA

Bug fixed:
==========
* Improved communication issues detection
* Minor bugs fixes
* Better integration in last Linux distribution

Known issues:
=============
None

Cyber-security:
===============
Please, visit www.eaton.com/cybersecurity to check the cyber-security status of this product and to subscribe to all cybersecurity alerts coming from Eaton.

Intelligent Power
2015-08-03Windows
VMWare
Intelligent Power Manager1.52 ========================================
Release note Intelligent Power Manager 1.52 for Windows
(January 2016)
========================================

New features:
=============
* Protect your VMware environment (including version 6) when both vCenter and IPM are virtualized
* Protect your Citrix environment with configuration policies and all advanced actions on virtualized infrastructures
* Remotely shutdown any SSH enabled server or storage.
* Create configuration policies from node selections
* Import and export configuration data files

Improvements
=============
* Send mail action now works through secure SMTP server
* IPM 1.51 is compatible with Java 1.8
* IPM 1.51 is compatible with Eaton ATS16
* Newly discovered nodes are now sorted by discovery date by default and located on top of the list
* Mass configuration of shutdown type of the nodes is now possible
* IPM 1.51 is translated into Chinese Simplified, Chinese Traditional, Czech, English, French, German, Italian, Japanese, Korean, Polish and Spanish.
Intelligent Power
2015-07-07Windows, Linux, VMware & HP-UX (Itanium)Intelligent Power Protector1.50========================================
Release note Intelligent Power Protector 1.50 for Windows
(June 2015))
========================================
Bug fixed:
==========
* Fix issue on upgrade procedure
* Events Calendar is no more limited to current year.
* Fix the root issue of loading error from AFS on WinSrv 2008 & WinSrv 2012.
* Virtual Power Source improvements:
** Status is better managed to avoid some unexpected shutdown.
** VPS can be used as a Power Source without restarting IPM Service
** VPS login/password correctly synchronized on source UPS
** VPS with Parallel UPS: Communication Lost with all connectUPS and Data Base error fixed
Known issues:
============
None

Intelligent Power
2015-07-07 WindowsEaton UPS Companion V1.04 ========================================
Eaton UPS Companion V1.04 - Release Note
June 2015
========================================

New features:
=======
* Nothing

Corrected problems:
==========
* Fix issue on upgrade procedure
* UAC enable EUC Systray start/stop impossible
* Activation Systray with UAC enable

Known issues:
=======
* Nothing
Eaton UPS Companion
2015-02-06Windows
VMWare
Intelligent Power Manager1.50 ========================================
Release note Intelligent Power Manager 1.50 for Windows
(March 2015)
========================================

New features:
=======
* Configuration policies: Use configuration policies to define and to share the power source settings, the protection and more.
* Configuration of custom actions.
* Configuration of custom events (not available in basic mode)
* Monitoring and management of individual VMs and vApps in VMware infrastructures.

Improvements:
=======
* Upgrade OpenSSL to version 0.9.8ze.
* IPM views are now sorted by alphabetical order.
* New fields available to customize body content of notification e-mails.
* SMTP port is configurable in Email actions.
* Notification e-mails coming from the software are no longer flagged as "Important" messages.
* VMware connector (updated to New VMware connector) allows the use of Configuration Policies and customized actions to set up the protection
* SRM configuration is now done through Configuration Policies and customized actions.
* VMware connector use now VMware events instead of polling.

Bugs fixes:
======
* IPM: no ESXi shutdown if some VM's shutdown hang
* Node access parameters setting is not possible for UCS blade
* STS-32 : Status Event alarms missing.
* VPS login/password are not correctly synchronized on source UPS.
* When we activate the plugin directly by creating the Vcenter connector , it is not taken into account.
* Storage Supervision is not possible: The communication with devices fails
* Menu Events Calendar: Events from previous year are no more visible on year change
* IPM Virtual Appliance - Auto Discovery does not work
* IPM Virtual Appliance - Unable to use the command "change driver node"
* Humidity is incorrectly displayed in mouse over tooltip.
* After uploading firmware on PDU, shutdown alarms for each outlets are triggered
* Linux Watchdog issue. The Application was not restarted automatically after a crash of the service.

Known issues:
=======
* If you monitor EX RT 3:1 UPSs including 66074 (old network card) and Network-MS (alias 66102) and you ask for the creation of a subview according to "Description", you will have 2 subviews with the same description "EX RT 3:1" instead of only one as it should be. You can move the nodes in one of this sub-view and delete the empty one manually.
* When using Configuration Policies with VPS power sources on load segments, use only shutdown timer setting from the configuration policy. If, instead, you use the shutdown timer configuration on each UPS, the setup won't work as expected.
* Only one Cisco UCS connector can be created at a time.
* Synology and HP Storages are no longer discovered by IPM but can still be used by:
** Running the corresponding address scan with the option "Force node creation",
** Using the link "Change node driver" to set the "NAS Synology / SNMP" driver.
* Node List filter "Create a sub view from": IPM does not take into account the already existing "Configuration Policies" view. All the Configuration policies available are added again systematically.
* Web Plugin VMware 5.1: The Eaton Widget is unavailable on vSphere Web Client for VMware 5.1. Please upgrade your installation to 5.5 if you want the Eaton Widget.
Intelligent Power
2015-02-06VMWareIntelligent Power Manager1.45bis ========================================
Release note IPM Virtual Appliance with IPM 1.45bis
(February 2015)
========================================

VA = Virtual Appliance

Operating System weakness fixes:
================
ICSA-14-353-01A (ntp):
- CVE-2014-9293
- CVE-2014-9294
- CVE-2014-9295
- CVE-2014-9296

Ghost (glibc):
- CVE-2015-0235

Known issues:
======
Manual driver selection for non-standard nodes management is not working in this version.
Intelligent Power
2014-11-28VMWareIntelligent Power Manager1.45 ========================================
Release note IPM Virtual Appliance with IPM 1.45
(November 2014)
========================================

VA = Virtual Appliance

New features
======
None

Bug fixed
=====
- Shellshock vulnerability is fixed
- The command "change driver node" is fixed.
- Auto Discovery mechanism works well

Known issues
======
None
Intelligent Power
2014-09-15VMWareIntelligent Power Manager1.44 ========================================
Release note IPM Virtual Appliance with IPM 1.44
(September 2014)
========================================

VA = Virtual Appliance

New features:
=======
None

Bug fixed:
=====
None

Known issues:
======
Manual driver selection for non-standard nodes management is not working in this version.
Intelligent Power
2014-09-15WindowsIntelligent Power Manager1.44 ========================================
Release note Intelligent Power Manager 1.44 for Windows
(September 2014)
========================================

New features:
=======
* Support for HP Managed and Monitored PDU (discovery, supervision, mass-configuration and mass-upgrade)
* Stronger default SSL settings
* Performance optimization on infrastructure connectors

Bug fixed:
=====
None

Known issues:
======
See 1.43 known issues.
Intelligent Power
2014-08-01VMWareIntelligent Power Manager1.43 ========================================
Release note IPM Virtual Appliance with IPM 1.43
(August 2014)
========================================

VA = Virtual Appliance

New features:
=======
* VA system upgraded to CentOS 6.5
* VA time synchronization through NTP

Bug fixed:
=====
* "Citrix XenCenter" and "Hyper-V" infrastructure connectors are not available anymore in VA as this functionnality is not available in VA
* Using new connectors fix system overload when VMware connector has incorrect password
* Lack of synchronization between status indicator on node list panel and in Selection View
* Fix "Invalid Certificate" error during VA deployment in vCenter

Known issues:
======
None
Intelligent Power
2014-08-01WindowsIntelligent Power Manager1.43 ========================================
Release note Intelligent Power Manager 1.43 for Windows
(August 2014)
========================================

New features:
=======
* Support for STS-32 using generic drivers
* VMWare Site Recovery Manager : Add the capability to start a site recovery plan when an power source event is launched
=> IPM 1.43 SRM feature has been validated with VMware 5.1, and should be compatible with VMware 5.5
* Ability to not restart a VM after its shutdown
* Gold licence required for virtualization features on Essential UPS models (9E, 93E, etc)


Bug fixed:
=====
* The password's characters could include non-ASCII characters now
* Using new connectors fix crash of IPM with many ESXi managed at the same time
* Redundancy, shutdown unexpected: for an unknown reason, the VPS status have not come back to the correct value
* No more instability after stop and restart of IPM on Windows Server 2012 or Windows 2008 R2
* No more alarm loss when ESXi enter in maintenance mode
* Fix availability of ESXi servers when added them just after removing them
* Fix vCenter Intelligent plugin version number registered into vCenter


Known issues:
======
None
Intelligent Power
2014-06-12VMWareIntelligent Power Manager1.42 ========================================
Release note IPM Virtual Appliance with IPM 1.42
(June 2014)
========================================

VA = Virtual Appliance

New features:
======
* Please refer to the IPM release note
* No specific new features for the IPM VA package

Bug fixed:
=====
* Please refer to the IPM release note
* No specific Bug Fixed for the IPM VA package

Known issues:
======
* Please refer to the IPM release note for IPM known issues

Specific IPM VA package known issues:
================
* No information/warning about unassigned power source for the "XenServer" infrastructure connector
* On the reboot of the VA, IPM needs at least 4 minutes to start.
* When a connector configuration file is broken, there is no way to remove it through the web interface

Intelligent Power
2014-05-19WindowsIntelligent Power Manager1.42 ========================================
Release note Intelligent Power Manager 1.42 for Windows
(May 2014)
========================================

New features:
======
* G3 ePDU integration: Eaton G3 ePDU are now mass-configuable and the firmware is mass-upgradable
* Italian language has been added

Bug fixed:
=====
* New connector supports vCenter installation non-default port
* ESXi type is now available to create a sub view of the node view
* Shutdown's sequences to NetappStorage are now logged correctly
* No more display delay for the IPM widget into vSphere Web Client
* No more issue when removing VMware vCenter Plugin connector
* Maintenance or shutdown orders work in new VMware vCenter connector even when activating the plugin directly at creation time
* Initial configuration of a new connector at creation time is now taken into account
* Robustness improvement of ESXi Maintenance mode management
* Robustness improvement of communication reliability with new connectors
* New connector Netapp Storage: No more communication loss when restarting the IPM service

Known issues:
======
None

Intelligent Power
2014-05-19Windows, Linux & VMwareIntelligent Power Protector1.42========================================
Release note Intelligent Power Protector 1.42 for Windows
(May 2014)
========================================

Bug fixed:
=====
* Fixed communication losses with Virtual Power Sources that could prevent IPP protection mechanisms to be launched properly

Known issues:
======
None

Intelligent Power
2014-02-24 WindowsEaton UPS Companion V1.03 ========================================
Eaton UPS Companion V1.03 - Release Note
(Febuary 2014)
========================================

New features:
=======
* UPS Compatibility:
- Eaton 5E

Corrected problems:
==========
* Nothing

Known issues:
=======
* Nothing
Eaton UPS Companion
2014-02-28Windows, Linux, VMware & UnixIntelligent Power Protector1.40========================================
Release note Intelligent Power Protector 1.40
(Febuary 2014)
========================================

Bug fixed:
=====
* Ubuntu with the Unity interface, The Open shortcut does not work.
* The status bar doesn't upgrade counters when adding or suppressing nodes.

Intelligent Power
2014-02-28 Windows & VMwareIntelligent Power Manager1.40========================================
Release note Intelligent Power Manager 1.40
(February 2014)
========================================

New features:
======
* Change driver node: after discovering a node, it's now possible to re-assign another driver to a node.
* Infrastructure Connectors (JRE prerequisite, please see the Licensing chapter in the user guide)
- Better integration of VMware vCenter.
- NetApp Storage management.
- Cisco UCS Management.
* vSphere web plug-in gives access to the power source status in the VMware vSphere.
* Ability to open CA’s Nimsoft platform from IPM.
* G3 ePDU integration.

Bug fixed:
=====
* The transfer to High Efficiency mode (on bypass) is now visible in the events list.
* 9130 UPS does shutoff at the end of the Shutdown duration.
* Fixing some problems with SCVMM and Maintenance Mode.
* Tabulations added in XenCenter are now different if it's a IPP or IPM.
* Fix VMware Mass Configuration Cache Problem.
* Removing IPM tab in vCenter, when removing the plugin.
* Error messages generated while VM shutdown and Turn on.
* MassConfig of the IPM shutdown settings is now available.
* Fixed level status for 9390 On Bypass mode in IPM
* Fixing different battery status depending on Power Source
* Fixing synoptic problem (on bypass).
* Fixing problem with IPM, when vCenter is installed on an non-default port.
* Fixing inconsistency value for load segment and shutdown duration, from a Network Management Card.
* The status bar does upgrade counters when adding or suppressing nodes.
* German language display is now consistent.

Known issues:
======
* When creating a first infrastructure connector checking the box "vCenter Plugin" may lead to unstabilities.
If you want to activate the vCenter plugin feature first create the connector without checking the vCenter Plugin box.
Then, edit your connector and check the box : all should work fine. If you have checked the box at creation time and
experience some unstabilities restart IPM (twice if needed) in order to get back to a normal state.

* With the JRE 7u45, the NetApp infrastructure connector, can lost the communication with the Netapp Storage after 2 days.
This issue does not appear with the JRE 7u40 and the last one 7u51.
Intelligent Power
2013-04-24Windows, Linux & VMwareIntelligent Power Protector1.30========================================
Release note Intelligent Power Protector 1.30 for Windows, Linux & VMware
(April 2013)
========================================

New features:
======
* Export nodes data into a CSV file.
* Compatibility with new Eaton UPSs: 9PX6KSP, 9PX8KSP, 9PX10KSP.
* SNMPv3 support for IPP data acquisition.
* IPP administrator has the possibility to definitely delete the old events from IPP database in order to reduce size and improve performance.

Bug fixed:
=====
* Value size restriction in shutdown timer and shutdown duration fields (999999 max seconds).
* Remove the Ascend/Descend sort capability for the "Messages" column in the Events panel.
* Update the battery icon in system tray, depending of the power source status.
* Icons display issues when using Windows Remote Desktop.
* Reduce time to detect a communication lost in RS232 mode.
* Event Calendar view issues.
* Display the temperature on ePDU products.
* Scan cancellation issue.
* Nodes suppression issue.
* Application crash on Debian, Fedora, Suse.
* Communication lost detection issue for client.
* Installation / Integration issues when Windows UAC is activated.

Known issues:
====== * There may be temporary inconsistency between the display counter for all the nodes, and the sum of nodes by status in the status bar after delete or discovery operations.
Intelligent Power
2013-04-24 Windows & LinuxIntelligent Power Manager1.30========================================
Release note Intelligent Power Manager 1.30 for Windows & Linux
(April 2013)
========================================

New features:
======
* "Generic driver" is a new and advanced feature which allows supervising any SNMP or NUT enabled device.
* Export nodes data into a CSV file.
* Synchronization of NetworkMS card security settings (except passwords).
* Compatibility with new Eaton UPSs: 9PX6KSP, 9PX8KSP, 9PX10KSP.
* SNMPv3 support for IPM data acquisition.
* Storage supervision (NETAPP, HP, SYNOLOGY, NETGEAR, QNAP, BUFFALO)
* For NETAPP storage it is also possible to trigger graceful shutdown from IPM.
* IPM administrator has the possibility to definitely delete the old events from IPM database in order to reduce size and improve performance.

Bug fixed:
=====
* Value size restriction in shutdown timer and shutdown duration fields (999999 max seconds).
* Remove the Ascend/Descend sort capability for the "Messages" column in the Events panel.
* Update the battery icon in system tray, depending of the power source status.
* Correct some labels in the mass configuration.
* Uninstallation of the SCVMM component issues.
* Icons display issues when using Windows Remote Desktop.
* Reduce time to detect a communication lost in RS232 mode.
* Event Calendar view issues.
* Display the temperature on ePDU products.
* Scan cancellation issue.
* Nodes suppression issue.
* Application crash on Debian, Fedora, Suse.
* Communication lost detection issue for client.
* Installation / Integration issues when Windows UAC is activated.

Known issues:
======
* There may be temporary inconsistency between the display counter for all the nodes, and the sum of nodes by status in the status bar after delete or discovery operations.
Intelligent Power
2013-04-24 WindowsEaton UPS Companion V1.02 Eaton UPS Companion V1.02
=========================

* UPS Compatibility:
- Eaton 5S
- Eaton Ellipse PRO

* Known issues
Nothing
Eaton UPS Companion
2012-12-13Windows & LinuxIntelligent Power Protector1.28========================================
Release note Intelligent Power Protector 1.28 for Windows & Linux
(December 2012)
========================================

New features:
=======
* Microsoft Windows 8 and Windows server 2012 compatibility
* VMware vCenter/ESXi 5.1 compatibility
* Citrix XEN 6.0 compatibility

Corrected problems:
==========
* Fix a crash when special network interfaces (vpn) under Linux are set.

Known issues:
=======
* On RS232 mode, when shutdown Criteria Output On Bypass is enabled, IPP is launching again the computer shutdown just after the restart.
* When Windows "User Account Control" (UAC) is enabled, the system tray icon
menu fails to send command. Use start and stop commands from Eaton Windows "Start" menu.
Intelligent Power
2012-12-13Windows & LinuxIntelligent Power Manager1.28========================================
Release note Intelligent Power Manager 1.28 for Windows
(December 2012)
========================================

New features:
========================
* Microsoft Windows 8 and Windows server 2012 compatibility
* Microsoft SCVMM 2012 compatibility
* VMware vCenter/ESXi 5.1 compatibility
* Citrix XEN 6.0 compatibility

Bug fixed:
======
* Removing vCenter plugin does not remove IPM tab in vCenter
* Fix a crash when special network interfaces (vpn) under Linux are set.

Known issues:
======
* With Microsoft SCVMM 2012 the communication can be lost in IPM when Virtual Machine enters in maintenance mode
* When Windows "User Account Control" (UAC) is enabled, the system tray icon
menu fails to send command. Use start and stop commands from Eaton Windows "Start" menu.
Intelligent Power
2012-10-26WindowsEaton UPS CompanionV1.00Eaton UPS Companion V1.00
=========================

* UPS Compatibility:
- Eaton 3S
- Eaton Ellipse ECO
- Ellipse
- Ellipse MAX
- Nova AVR
- Protection Station
- Protection Center

* Known issues
- When Windows "User Account Control" (UAC) is enabled,
the system tray icon menu fails to send command.
Opening the UPS Companion display from the icon could also fail.
Use start, stop and open commands from Eaton Windows "Start" menu.
- When Windows "User Account Control" (UAC) is enabled, the system tray
notification setting could also fail to start or stop the notification
application. A restart of session after setting should solve the problem.
- The manual reset of energy counter should be effective only after a restart
of UPS Companion service.
- The setting of energy cost will be display in status panel after closing
and re-opening UPS Companion display.
Eaton UPS Companion
2012-10-01WindowsNetwork-MS cardHF=========
Release HF
=========

New features:
- Compatibility with Eaton 9P.
- Compatibility with some new models Eaton 9E.
- Compatibility with Eaton 5P, 9SX and 9PX single phase.
- NMC retrieves the power usage data managed by the UPS, they are returned in new Oid in the Eaton PowerMIB for UPS and in the Power Usage new web page.
Embedded software
2012-09-04Windows & LinuxIntelligent Power Protector1.26New features for Intelligent Power Protector 1.26:
=========================
* Package digital signature.
* Redundancy behavior improvement: The power lost is
now detected only when the count of units powered by
the utility is lower than the requested unit for the load.
* New parameters available in command line installation
mode. Use '-help' option for complete command line
format description.

Corrected problems:
==========
* Fix issue 1.20-2
* Bug fix in measures database.
* "Shutdown controller" module issue: No shutoff
in some specific conditions

Known issues:
=======
None
Intelligent Power
2012-08-28WindowsIntelligent Power Manager1.27New features for Intelligent Power Manager 1.27: ========================

Bug fixed:
======

* Virtualization Module: When IPM was configured for the VMware HA Mode,
it didn't wait enough time after the shutdown of the VMs to shutdown
the ESXi servers

Known issues:
======
* For IPM Virtual Appliance only, the statistics and the graph are not
available for the nodes. The graph panel is empty (no measures and no curves).
The statistics panel is not refreshed (no statistics displayed).
Intelligent Power
2012-05-15WindowsIntelligent Power Manager1.26New features for Intelligent Power Manager 1.26:
========================

* Virtualization module improvements:
Adds the possibility to shutdown the VMware virtual machines from IPM (even in VMware HA mode)
* Package digital signature
* Redundancy Behavior (the Virtual Power Source (VPS) will be in Alarm state
when all the PowerSource components are in Alarm state)

Bug fixed:
======

* VMware vCenter connection issue (Occured when the username was entered
like Domain/Username in IPM and in vCenter active session the username
was resolved as "username")
* VMware ESX/ESXi shutdown issue (The shutdown initiated by IPM didn't force
the shutdown, the shutdown didn't work when the VMware ESX/ESXi was not
in maintenance mode)
* (RS232) Random UPS ShutOff issue
* Communication lost with Virtual Power Source (This bug appeared in IPM 1.25
version)
* NMC Mass Upgrade issue when the card is in SSL mode is fixed on this release.
Intelligent Power
2011-12-19WindowsIntelligent Power Manager1.25New features for Intelligent Power Manager 1.25:
========================

* IPM 1.25 can now "Mass Configure" and "Mass Upgrade" the Network card of the new Eaton Advanced ePDU:
=> Europe = Switched (SW), Advanced Monitored (AM) and Managed (MA)
=> US= Advanced Monitored (AM) and Managed (MA))

* VMware integration improvements:
Suppress the VMware Perl SDK prerequisite
vCenter Plug-in: Create more Alarms and Power Events in vCenter
Can now Add/Protect a Standalone ESX/ESXi in IPM without vCenter

* XenServer integration (new)
Remote Shutdown from IPM
Remote Maintenance from IPM
Can Add/Protect a XenServer in IPM

* XenCenter integration (new)
Create a XenCenter Plug-in from IPM

* IPM is shown as a “Notified Application” in the NMC/Network-MS card when a VMHost’s node has a UPS configured in IPM.
Intelligent Power
2011-10-19Windows & LinuxIntelligent Power Protector1.20New features for Intelligent Power Protector 1.20:
========================
* Implements new UPS redundancy management feature (refer to user manual)
* Compatibility with latest Linux distributions (refer to user manual)
* Shutdown script for Xen and KVM is now integrated in IPP
* Improved supervision of Eaton 5PX UPS
* Improved system tray icon with contextual menu available through right click
* Database log size has been optimised.
* Statistics provide now device consumption in kWh instead of kVAh.
* A UPS configuration panel appears in shutdown menu (RO with network Power
Source and RW with serial line Power Source)
* Shutdown controller feature is now compatible with Network card
Intelligent Power
2011-10-19WindowsIntelligent Power Manager1.20New features for Intelligent Power Manager 1.20:
========================

* Implements a new UPS redundancy management feature (refer to user manual)
* IPM 1.20 can supervise and discover the new Eaton Advanced ePDU:
=> Europe = Switched (SW), Advanced Monitored (AM) and Managed (MA)
=> US= Advanced Monitored (AM) and Managed (MA))
* IPM 1.20 has been tuned for new 5PX UPSs supervision.
* Improved system tray icon with contextual menu available through right click
* Database log size has been optimised.
* Statistics provide now device consumption in kWh instead of kVAh.
* SNMP acquisition drivers have been optimised.
* HP UPSs can be supervised (management feature is not supported)
* Dell UPSs can be supervised (management feature is not supported)
* IBM UPSs can be supervised (management feature is not supported)

When "Shutdown" feature is activated:
===================
* a UPS configuration panel appears in shutdown menu (Read only with network Power Source and Read Write with serial line Power Source)
* Shutdown controller feature is now compatible with Network card


Corrected bug:
=======
IPM 1.20 can mass upgrade Network-MS HE revision
Intelligent Power
2011-02-01WindowsIntelligent Power Manager1.14New features for Intelligent Power Manager 1.14:
========================

Intelligent Power Manager is compatible with VMware vCenter 5.0.
We advise you to install vCenter 4.0, 4.1 or 5.0 with default HTTPS port (443) for a correct integration with IPM

===

Intelligent Power Manager 1.14 can manage the local computer shutdown now also with following cards (Connect UPS-BD, Connect UPS XLot, PXGX 2000).
Note: this feature is only available if you install IPM 1.14 on a computer that is NOT hosting a previous IPM release.

If you have upgraded IPM from 1.XX to 1.14 release and want to use this feature, please proceed as follows:
=> Stop IPM service
=> Remove (or rename) the configuration file: configs/config.js
=> Start IPM service
=> If needed, reconfigure system parameters
Intelligent Power
2011-01-07WindowsIntelligent Power Manager1.13New features for Intelligent Power Manager 1.13:
========================
Intelligent Power Manager 1.13 has a new Virtualisation module.
This module can integrate IPM in VM-Ware vCenter and Microsoft SCVMM to provide advanced management features for these Hypervisors
Please refer to the IPM User Manual for a description of these advanced and powerful features.
Intelligent Power
2010-09-15Windows and LinuxIntelligent Power Protector1.10New features for Intelligent Power Protector 1.10:
========================
* Initial release compatible with Eaton UPSs (Pulsar & Powerware 1 ph/3ph) except ferrups. Refer to the compatibily list.
* Note: Intelligent Power Manager 1.12 that is able to supervise and manage IPP 1.10 is available free of charge on the web download or through
Automatic Update Process.
Intelligent Power
2010-09-15WindowsIntelligent Power Manager1.12New features for Intelligent Power Manager 1.12:
========================
a) Intelligent Power Manager 1.12 is able to supervise and manage IPP 1.10

b) Compatibility with serial and USB Eaton UPSs

c) Compatibility with shutdown controller feature

d) Security enhancement

e) Link to online help added

f) Known limitation:
Intelligent Power Manager 1.12 is compatible with PXGX2000/Connect UPS XSlot/BD
for supervision purpose only
=> Shutdown feature with these cards will be available in a next release
Intelligent Power
2010-02-16WindowsIntelligent Power Manager1.11New features for Intelligent Power Manager 1.11: ========================
a) New supported languages:
Czech, Chinese Simplified, Japanese, Portuguese

b) New feature "USB / Serial" UPS data acquisition
supervision and protection feature through USB and serial
(for Pulsar Range only)

c) bug corrections
- Better management of multiple monitored ePDUs
- Better APC UPS support
- Correct issue with shortcut in Asian languages
Intelligent Power
2009-10-16Windows SevenSoftware suiteNAThe Pulsar software suite is compatible with Windows 7:
- Personal Solution Pac
- Microsoft Integrated Power Management
- Network Shutdown Module
- Intelligent Power Manager
Solution Pac 2
2009-10-15Mac OSX 10.6NSM and Integrated Power ManagementNAEaton software suite is fully compatible with Mac OS X 10.6 (Snow Leopard) - Apple Integrated Power Management - Network Shutdown Module 3.20Solution Pac 2
2009-08-29WindowsIntelligent Power Manager1.10Intelligent Power Manager 1.10 is now fully compatible with Eaton Powerware 3 Phase UPSsEaton Software
2009-06-10WindowsIntelligent Power Manager1.00New Eaton Web Based Supervision ToolEaton Software
2009-06-01LinuxNSM and PSPNAThese products are now compatible with x86_64 platformSolution Pac 2
2009-02-11Hyper-V ServerNetwork Shutdown Module3.20Network Shutdown Module for Windows is compatible with Hyper-V and Hyper-V ServerSolution Pac 2
2009-01-16embeddedNMC 66102FAStack Update Enotify compatibilitySolution Pac 2
2009-01-15LinuxPersonal Solution Pac3.0.8Compatibility with Protection Station Eaton Look and FeelSolution Pac 2
2008-12-10WindowsPersonal Solution Pac2.61Compatibility with Protection Station Eaton Look and feelSolution Pac 2
2008-12-01LinuxNetwork Shutdown Module3.20New default login and password
Compatibility with Eaton EX UPS family
New Eaton look and feel
Bug correction
Advanced Manageability through EPM 2.20
Solution Pac 2
2008-12-01Mac OSXNetwork Shutdown Module3.20New default login and password
Compatibility with Eaton EX UPS family
New Eaton look and feel
Bug correction
Advanced Manageability through EPM 2.20
Solution Pac 2
2008-11-21WindowsEnterprise Power Manager2.20- Eaton EX UPS family compatibility
- New Eaton look and feel
- Mass configuration of NMC cards and NSM
- New installator
- Bug correction (C.f. release note)
Solution Pac 2
2008-10-10WindowsNetwork Shutdown Module3.20New default login and password
Compatibility with Eaton EX UPS family
New Eaton look and feel
Bug correction
Advanced Manageability through EPM 2.20
Solution Pac 2
2008-09-01WindowsEnterprise Power Manager2.10Compatibility with Eaton Managed and Eaton Monitored PDUsSolution Pac 2
2008-04-23WindowsNMC Tool 1.5 & NMC Card /EA1.5 & EAMass configuration feature is now available with:
NMC Tool 1.5
NMC Card 66102 /EA Min
Embedded
2008-04-11Windows Server 2008IPM, PSP, NSM, EPMLatestValidation team tested succesfully these products with:
2008 (Web Server, Standard, Entreprise, Data Center)
Windows Server 2008 Enterprise x64 Edition
Solution Pac 2
2008-03-04Mac OSXNetwork Shutdown Module3.10Official Release
Unique Technical Benefits of Network Shutdown Module V3.10 for Mac OSX:
Compatibility with Mac OSX 10.4, 10.5 (Universal binary for Intel and PowerPC)
Solution Pac 2
2008-02-27Embedded FirmwareNetwork Management CardDA- Compatibilty with EX 5 / 7 / 11 RT (with minislot [Q2 08])
- User Interface with MGE Office Protection Systems look & feel
- Increase of the supported NSM number (up to 100)
Embedded software
2008-02-04Mac OSXNetwork Shutdown Module3.10 BetaUnique Technical Benefits of Network Shutdown Module V3.10 for Mac OSX:
 Compatibility with Mac OSX 10.4, 10.5 (Universal binary for Intel and PowerPC)
Intuitive Web interface with Safari and Firefox
Compatibility with the major power redundancy modes ideal for multiple feed servers like Apple Xserve.
Beta Test Area
2008-01-30WindowsNetwork Shutdown Module3.10New features:
Broadcast protocol for alarms reception. (with 66102 /DA [Q1 08])
Quick scan of the Network Management Cards.
Automatic configuration of the Windows firewall.
Solution Pac 2
2008-01-10WindowsPersonal Solution Pac2.53MGE Office Protection Systems Look and feel
This version is compatible with latest UPS models:
Protection Center 600/750
Nova AVR 625/1250
Pulsar M - US version
Solution Pac 2
2007-12-22LinuxNetwork Shutdown Module3.04Compatible with MGE Office Protection Systems UPSsSolution Pac 2
2007-12-20LinuxPersonal Solution Pac3.0.6MGE Office Protection Systems Look and Feel
bug fix
Solution Pac 2
2007-11-17Embedded FirmwareIndustrial Network Management CardAANew The 66103 Minislot card benefits from all the network features of the 66102 card. In addition the 66103 card benefits from the Modbus and JBus Communication.Embedded software
2007-11-16WindowsNetwork Management Card Tool1.00This new tool allows network discovery and mass upload of the Network Management Cards (66102, 66103, 66074, ...)Embedded software
2007-11-05WindowsEnterprise Power Manager2.08Enterprise Power Manager with MGE Office Protection Systems look & feelSolution Pac 2
2007-11-05WindowsNetwork Shutdown Module3.04Network Shutdown Module with MGE Office Protection Systems look & feelSolution Pac 2
2007-11-05WindowsNetwork Management Proxy5.02Windows Vista compatibilitySolution Pac 2
2007-09-14LinuxPersonal Solution Pac3.0.4a) Compatibility with the latest distributions (Hotplug USB solved, binary compatibility, ...), b) Several bugs solved and significative enhancements, c) Compliant with the Ubuntu distribution.Solution Pac 2
2007-06-04WindowsEnterprise Power Manager2.07Compatibility with latest APC Network Management CardsNetwork Supervision
2007-05-23LinuxNetwork Shutdown Module V33.02Multilingual Package
Compatibility with many Linux distributions (Debian, Ubuntu, Redhat, Suse-Novell, ...)
Compatibility with VMWare ESX
Compatibility with IBM Blade Centers
Bug corrections
Network Offer
2007-05-14WindowsPersonal Solution Pac2.51This version is compatible with latest UPS models:
1) Pulsar MX Frame 16 U
2) Pulsar 700/1000/1500/1000 RT2U/1500 RT2U [US Models Q4-07]
Solution Pac 2
2007-05-09Windows Vista, 2003, XP, 2000Network Shutdown Module V33.02Multilingual Package
Compatibility with Microsoft Virtual Server
Bug corrections
Network Offer
2007-03-26LinuxPersonal Solution Pac3.0.2 betaa) Compatibility with the latest distributions (Hotplug USB solved, binary compatibility, ...),
b) Several bugs solved and significative enhancements,
c) Compliant with the Ubuntu distribution.
Solution Pac 2
2007-03-13Windows (incl Vista)Enterprise Power Manager2.06New Features:
Windows Vista compatibility and many other improvements documented in the Release Note.
Network Supervision
2007-03-05Windows VistaIntegrated Power ManagementNAThe Vista native Integrated Power Management has been tested succesfully with MGE UPS UPSs (refer to documentation)Solution Pac 2
2007-01-17Windows Vista, 2003, XP, 2000Network Shutdown Module V33.00This new software is released for features evaluation (Multi -UPS configurations, remote access, no JVM pre-requisites ...)Network Offer
2007-01-10Windows VistaPersonal Solution Pac2.50This version is compatible with Windows VistaSolution Pac 2
2007-01-10Windows VistaPersonal Solution Pac2.50 BetaThis beta version is compatible with Windows VistaSolution Pac 2
2006-10-23WindowsNetwork Management Proxy V55.01Compatible with latest UPSs
Improved graphical interface
Password protection and https
communication
Web server proposed with the product
MGE Network Solution
2006-10-16WindowsEnterprise Power Manager2.05New Features:
Multilingual (Chinese, Deutsch, Dutsch, English, Espa?ol, Fran?ais, Italiana, Norsk)
Quick Scan function
Network Supervision
2006-10-11WindowsPersonal Solution Pac2.40This version includes following features:
a) advanced electrical settings for Ellipse MAX and new evolution,
b) improved Life Cycle Monitoring management.
Solution Pac 2
2006-09-19Linux (x86)Network Shutdown Module V3 BetaBetaThis new software is released for features evaluation (Multi -UPS configurations, remote access, no JVM pre-requisites ...)Network Offer
2006-08-31WindowsNetwork Shutdown Module V3 BetaBetaThis new software is released for features evaluation (Multi -UPS configurations, remote access, no JVM pre-requisites ...)Network Offer
2006-07-07WindowsEnterprise Power Manager2.00New Features:
A simple and very powerful representation mode lets you create your electrical supervision diagram using a web browser.
New devices compatibility:
a) STS-Web card ? 66073 (for Upsilon Static Transfer Switch)
b) Static Switch Cabinet through Network Management Link (device supported as beta)
c) Computers hosting Network Shutdown Module V3 (Should be released as beta end of Q3 06 and as official version Q4 06)
Network Supervision
2006-06-30Mac OS X Intel Core DuoIntegrated Power Management & Network Shutdown Module10.4.6The native Integrated Power Management has been tested succesfully with MGE UPS UPSs (refer to documentation) The Network Shutdown Module V2.6 has been tested succesfullySolution Pac 2
2006-05-18WindowsPersonal Solution Pac2.38This version includes advanced electrical settings for Pulsar MX.Solution Pac 2
2006-04-13Sun Solaris 10 x86Network Shutdown Module2.6 BetaA Beta version of Network Shutdown Module 2.6 is provided.Solution Pac 2
2006-03-10WindowsPersonal Solution Pac2.37New UPS compatibility:
* EX 5 RT Asia/Pacific (a)
* Pulsar 700/1000/1500/1000 RT2U/1500 RT2U (a)
* Pulsar M (a)
* Pulsar MX (b)
* Evolution 650/ 850/ 1150/ S 1250/ 1550/ S 1750/ 2000/ S 2500/ S 3000 (b)
(a)incl. advanced electrical settings
(b)without advanced electrical settings
Solution Pac 2
2006-01-13All systemsNetwork Shutdown Module2.6Network Shutdown Module has been tested compatible with:
* Linux Debian Sarge, SUSE 10.0, Mandriva LE2006, Redhat ES 3,
* Solaris 10 (SPARC),
* AIX 5.3 (RS6000),
* Netware 6.5.
Sustaining problems are corrected in this release, refer to package Release Note
Solution Pac 2
2006-01-12Solaris, AIX, NetwarePersonal Solution Pac2.0Personal Solution Pac has been tested compatible with:
* Solaris 10 (SPARC)
* AIX 5.3 (RS6000)
* Netware 6.5
Solution Pac 2
2005-12-15WindowsSnap-In for HP SIM4 & 51.1The 1.1 kit is compatible with the latest HP NMS version HP SIM 5NMS
2005-10-20WindowsEnterprise Power Manager1.20The 1.20 version improves performance and stability and is compatible with the Knuerr Rack Monitoring systems
The 1.20 version also improves the MGE Switched PDU and ServerTech PDU supervision.
Sound notification can be sent on specific event occurrence.
Network Supervision
2005-10-07WindowsPersonal Solution Pac Multilingual2.35Multilingual packages: Espa?ol, Deutsch, Italiana, Norsk, Portugu?s.Solution Pac 2
2005-09-29WindowsPatch for Personal Solution Pac2.35This patch is specific for Comet EX 5 RT Asia/Pacific.
With this patch you can configure UPS electrical settings
Solution Pac 2
2005-09-22WindowsNetwork Management Proxy5.00 betaRefer to the release note for benefits and limitationsSolution Pac 2
2005-09-22WindowsIntegrated Power ManagementNAMicrosoft Integrated Power Management solution has been documented for USB UPSsSolution Pac 2
2005-09-08LinuxPersonal Solution Pac3.0Simple, Graphical and USB enabled:
Personal Solution Pac 3.0 is the new point-to-point Power Management Software for Linux.
(Released under GPLV2 Licence)
Solution Pac 2
2005-08-24Mac OSX 10.4Mac OSX Integrated Power Management and PSP10.4.2Integrated Power Management has been tested compatible with MGE UPSs and PSPSolution Pac 2
2005-07-06WindowsPersonal Solution Pac2.35Descargue Personal Solution PAC 2.35 Edici?n en Espa?ol para Windows.Solution Pac 2
2005-06-09Mac OSX 10.4Network Shutdown Module2.5Network Shutdown Module has been tested compatible with Mac OX 10.4.1 and Sun JVM 1.5.3Solution Pac 2
2005-05-03WindowsPersonal Solution Pac2.35Personal Solution Pac is released with new UPS compatibility for Ellipse 600/750/1000/1500 USBSSolution Pac 2
2005-02-23WindowsSnap-In for HP SIM41.0Supervision of MGE UPSs using HP-SIM4.
Sensor traps can be received.
NMS
2005-02-15WindowsEnterprise Power Manager1.10The 1.10 version improves performance and is compatible with these devices:
* MGE Switched PDU NM - 68130/68134/56132/56134/56136/56138
* MGE AmpMeter PDU NM - 68152/56134/56144
* MGE Midspan NM - 66892
* PowerDsine series 6000
Enterprise Power Manager 1.1 has been tested with 1000 devices in Gold version
Network Supervision
2005-02-09WindowsPersonal Solution Pac2.34Personal Solution Pac is released with new features:
1) New UPS compatibility (NOVA AVR 600/1100 and Comet EX 5/7/11 RT 3:1)
2) "Mail to" on UPS events
3) Patch20040903
Solution Pac 2
2005-02-09WindowsNetwork Management Proxy4.06Personal Solution Pac is released with new features:
1) New UPS compatibility (NOVA AVR 600/1100 and Comet EX 5/7/11 RT 3:1)
2) "Mail to" on UPS events
3) Patch for Network Management Proxy 4.05 is integrated
Solution Pac 2
2004-12-03WindowsEnterprise Power Manager (5-nodes)1.0The new MGE UPS supervision tool is dedicated to power management functions. You can use for free the 5-nodes version.Network Supervision
2004-10-22All systemsSolution Pac 2HASolution Pac 2 is released with new HTML navigator.
MGE Network Shutdown offers following functions:

* First function is UPS Network conection:
---------------
=> through Net Mgt Card
=> or through Mgt Proxy; previously named XML-Agent).

* Second Function is Computer Shutdown:
---------------
=> through Network Shutdown Module (previously named XML-Client).

* Third Function is Supervision:
---------------
=> through Web Browser
=> or through NMS Integration kit on Management Pac 2 CD-Rom
=> or through Enterprise Power Manager (still under Beta test)
Solution Pac 2
2004-05-25All systemsPersonal Solution-Pac and Solution-Pac WANGJCompatibility with new UPSs: Comet EX 5/7/11 RT and Pulsar EX 700/1000/1500 RT). new features: - UPS lifecycle supervision - UPS settings - UPS Maintenance/ Configuration and diagnostic facilitySolution-Pac
2004-05-20FirmwareSNMP/Web CardDBFollowing new UPS are now supported : Pulsar EX 700, 1000, 1500 RT and EX 5, 7, 11 RT - Fix that the UPS picture was missing for COMET UPS. - Suppress the dependence between Shutdown after on master output and switchoff After on controlled outlets. - Fixed that the password was reset to default value after a reset card.Embedded
2004-03-26FirmwareSNMP/Web CardDACompliant with the Environment Sensor : Temperature and humidity measurement 2 external contacts management New html pages for Environment Sensor control New features : Direct Email and SMS notification New html page for UPS ON/OFFcontrol New html page for Shutdown parametersEmbedded
2004-03-22WindowsPersonal Solution Pac (Spanish Edition Package)GHDescargue Personal Solution PAC / GH Edici?n en Espa?ol para Windows.Solution-Pac
2004-02-26WindowsSnap-In for HP-Openview NNM 6.3/6.4 &71.2Compatibility with NNM7 and Windows Server 2003. Sensor traps can be received.NMS
2004-02-26WindowsSnap-In for Insight Manager 71.6New automated Installation procedure described in User documentation. Uninstall feature is added. Sensor Traps can be received.NMS
2004-02-23FirmwareXML-Web CardSAUpsilon & Epsilon STS Monitoring (specific release)Embedded
2004-02-23FirmwareSNMP/Web CardCCAdd compatiblility with the new MGE UPS Models: EXtreme 2200/3200C & EX 2200/3200 RTEmbedded
2004-02-04All systemsPersonal Solution-Pac and Solution-Pac WANGHPoint to point and snmp solutions are compatible with the new MGE UPS Models: EXtreme 2200/3200C & EX 2200/3200 RTSolution-Pac
2004-02-04WindowsUPS-Driver1.4UPS Configuration Software is compatible with the new MGE UPS Models: EXtreme 2200/3200C & EX 2200/3200 RTEmbedded
2004-02-03Windows Server 2003XML-Client2.0XML-Client 2.0 is compatible with Windows Server 2003UPS Web-Pac
2004-02-03WindowsJericho3.063Telecom Driver update concerning SMS/Pager alert fonction through XML-Client Windows (for more details refer to release note)UPS Web-Pac
2004-01-13Novell Netware 5/6XML-Client2.0XML-Client 2.0 including Event-Actions config through Advanced GUI, Email notification.UPS Web-Pac
2004-01-07Sun Solaris SparcXML-Client2.0XML-Client 2.0 including Event-Actions config through Advanced GUI, deployment facilities and Email notification.UPS Web-Pac